Seitenansicht 25
2-12
MS-96C8 Server Board
Fan Power Connector: CPU0_FAN, CPU1_FAN, SYS_FAN1/2/3/4/5
The fan power connectors support system cooling fan with +12V. When connecting
the wire to the connectors, always note that the red wire is the positive and should
be connected to the +12V; the black wire is Ground and should be connected to GND.
If the mainboard has a System Hardware Monitor chipset onboard, you must use a
specially designed fan with speed sensor to take advantage of the CPU fan control.
Important
Please refer to the recommended CPU fans at processors official website or
consult the vendors for proper CPU cooling fan.
Serial Port Connector: COM2
This connector is a 16550A high speed communications port that sends/receives 16
bytes FIFOs. You can attach a serial device to it through the optional serial port
bracket.
PIN SIGNAL DESCRIPTION
1 DCD Data Carry Detect
2 SIN Serial In or Receive Data
3 SOUT Serial Out or Transmit Data
4 DTR Data Terminal Ready
5 GND Ground
6 DSR Data Set Ready
7 RTS Request To Send
8 CTS Clear To Send
9 RI Ring Indicate
Pin Definition
CPU0_FAN
SENSOR
+12V
GND
CONTROL
CPU1_FAN,
SYS_FAN4
SENSOR
+12V
GND
CONTROL
SYS_FAN1/2/3/5
SENSOR
+1 2V
GND
CONTROL