Report No.: 048L022EI
Page: 16 of 35 Version:1.0
5.5. Test Procedure
The EUT and its simulators are placed on a turn table which is 1.5 meters above ground. The turn table
can rotate 360 degrees to determine the position of the maximum emission level. The EUT was
positioned such that the distance from antenna to the EUT was 3 meters.The antenna can move up and
down between 1 meter and 4 meters to find out the maximum emission level.
Broadband antenna (calibrated bi-log and horn antenna) are used as a receiving antenna.
Both horizontal and vertical polarization of the antenna are set on measurement. And a high frequency
preamlifier were used increase the sensitivity of the measuring. In order to find the maximum emission,
all of the interface cables must be manipulated according to ETSI EN 300 328:V1.4.1 (2003-04) on
radiated measurement.
The additional notch filter below 1GHz was used to measure the level of harmonics radiated emission
during field dtrength of harmonics measurement. The bandwidth setting on the field strength meter (R
& S Spectrum Analyzer FSP40 )is 100 kHz. The frequency range from 30MHz to 12.75GHz is
checked.
5.6. Uncertainty
The measurement uncertainty above 1G is defined as
±
3.9 dB
under 1G is defined as ± 3.8 dB
5.7. Test Specification
According to ETSI EN 300 328:V1.4.1 (2003-04)
5.8. Test Result
The emission from the EUT was below the specified limits. The worst-case emissions are shown in
section 8. The acceptance criterion was met and the EUT passed the test.
Seitenansicht 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 43 44

Kommentare zu diesen Handbüchern

Keine Kommentare