Issue Date: 2003-09-25 Page 23 of 42 Report Reference #
E203413-A17-CB-1
IEC 60950
Clause Requirement + Test Result - Remark Verdict
TRF No.: 1950__F UL International Demko A/S TRF originator: FIMKO
4.5 Thermal Requirements Pass
4.5.1 Temperature rises (see appended table 4.5) Pass
Normal load condition per Annex L......................:
Operated in the most
unfavorable way of operation
given in the operating
instructions until steady
conditions established.
Pass
4.5.2 Resistance to abnormal heat It has been determined from
examination of the physical
characteristics of the materials
used that the material meets
the requirements of the test.
See Appended Table 4.5.2.
Pass
4.6 Openings in Enclosures N/A
4.6.1 Top and side openings No opening. N/A
Dimensions (mm)...............................................:
-
4.6.2 Bottoms of fire enclosures No bottom opening. N/A
Construction of the bottom ..................................:
-
4.6.3 Doors or covers in fire enclosures
N/A
4.6.4 Openings in transportable equipment
N/A
4.6.5 Adhesives for constructional purposes
N/A
Conditioning temperature/time ............................:
-