Issue Date: 2003-09-25 Page 6 of 42 Report Reference #
E203413-A17-CB-1
IEC 60950
Clause Requirement + Test Result - Remark Verdict
TRF No.: 1950__F UL International Demko A/S TRF originator: FIMKO
1.6 Power Interface Pass
1.6.1 AC power distribution systems AC power distribution systems
are classify as TN.
Pass
1.6.2 Input current The steady state input current
of the equipment did not
by more than 10% under
NORMAL LOAD.
(see appended table 1.6.2)
Pass
1.6.3 Voltage limit of hand-held equipment Not hand-held equipment. N/A
1.6.4 Neutral conductor Class II equipment. Phase
conductors separated to body
by reinforced insulation.
Pass